Description |
Sensor type |
integrated circuit temperature sensor with six plate radiation shield |
Applications |
• wind resource assessment • meteorological studies • environmental monitoring |
Sensor range |
-40 ¡ÆC to 52.5 ¡ÆC (-40 ¡ÆF to 126.5 ¡ÆF) |
Instrument compatibility |
all NRG loggers |
Output signal |
Signal type |
linear analog voltage |
Transfer function |
Temp = (Voltage x 55.55) - 86.38 ¡ÆC [Temp = (Voltage x 100) - 123.5 ¡ÆF] |
Accuracy |
• within +/- 1.11 ¡ÆC (2 ¡ÆF) • nonlinearity is +/- 0.33 ¡ÆC (+/- 0.6 ¡ÆF) maximum |
Electrical time constant |
250 ¥ìs |
Output signal range |
0 V to 2.5 V DC |
Power requirements |
Supply voltage |
4 V to 35 V DC |
Supply current |
300 ¥ìA max. (no load on output) |
Response characteristics |
Thermal time constant |
5 minutes |
Installation |
Mounting |
attaches to tower with included hose clamps |
Tools required |
• sheet metal shears or similar for trimming hose clamps • 5/16 inch hex driver or flat blade (-) screwdriver |
Environmental |
Operating temperature range |
-40 ¡ÆC to 52.5 ¡ÆC (-40 ¡ÆF to 126.5 ¡ÆF) |
Operating humidity range |
0 to 100% RH |
Lifespan |
10 years + |
Physical |
Connections |
wire leads: • signal (clear wire) • ground (black wire) • excitation (red wire) • shield wire for earth ground |
Cable length |
5 m (16 feet) |
Weight |
0.47 kg (1.04 pounds) |
Dimensions |
• sensor only: 30.5 mm (1.2 inches) height x 12.7 mm (0.5 inch) diameter • sensor with radiation shield: 127 mm (5 inches) diameter x 127 mm (5 inches) height |
Materials |
Cable |
3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket |
Probe |
aluminum, epoxy filled |
Shield |
UV-stabilized thermoplastic solar radiation shield |