    Á¦Ç°¼Ò°³    NRG #40 Anemometer
NRG #40
Anemometer
 
 
The NRG #40C anemometer is the industry standard anemometer used worldwide. NRG #40 anemometers have recorded
wind speeds of 96 m/s (214 mph).
Their low moment of inertia and unique bearings permit very rapid response to gusts and lulls.
Because of their output linearity, these sensors are ideal for use with various data retrieval systems. A four pole magnet
induces a sine wave voltage into a coil producing an output signal with a frequency proportional to wind speed.
The #40C is constructed of rugged Lexan cups molded in one piece for repeatable performance.
A protective rubber terminal boot is included.

FEATURES
• The standard anemometer used in the wind energy industry
• Short distance constant
• Voice call feature allows on-site programming and testing of iPack communications.
• Simple, durable design

 

SPECIFICATIONS

Description Instrument type 12 channel internet-enabled micropower wind energy data logger
Applications • wind resource assessment
• turbine power performance verification
Sensor compatibility -
counter channels
• NRG #40 anemometer
• rain gauge
• opto anemometer
• reed switch anemometer
Sensor compatibility -
analog channels
• NRG 200P direction vane
• NRG 110S temperature
• Li-Cor 200SA pyranometer
• NRG BP-20 absolute pressure (requires optional iPack power)
• RH-5 relative humidity (requires optional iPack power)
Data
Collection
Counter channels Channels 1 - 6 are always counter inputs:
• channels 1 - 3 dedicated for NRG #40 anemometer or compatible
• channels 4 - 6 use counter Signal Conditioning Modules (SCMs)
  to configure the channel for a particular sensor
Analog channels Channels 7 - 12 are always analog inputs:
• channels 7 and 8 dedicated for NRG 200P (potentiometer) direction vane
• channels 9 - 12 use analog Signal Conditioning Modules (SCMs) to
  configure each channel for a particular sensor
Sampling interval 2 seconds
Averaging interval 10 minute fixed
Real time clock internal battery-backed with leap year correction, Y2K to 2099
Storage medium 16 MB MultiMedia Card (MMC), non-volatile FLASH
Maximum data storage 664 days
Parameters
recorded for
each channel
• each data interval is time-stamped
• average
• standard deviation
• min
• max
File format • Windows compatible
• (1) 14 KB binary file per day
• header includes site, serial number and sensor information
Software Symphonie Data Retriever for Windows (included)
• scales raw data
• creates measurement database for each site
• creates basic reports
• maintains site and sensor information
• configures iPacks
Reader Windows compatible MMC reader accesses data stored on MMC as disk
files
Data delivery • MMC cards
• internet email via GSM, AMPS or dial-up with optional iPack
Resolution Analog measurement
resolution
0.1% of full scale (1024 counts)
Counter average
stored resolution
0.1% of the value stored
Analog average
stored resolution
0.1% of the value stored
Min / Max stored
resolution
0.3% of the value stored
Standard deviation
stored resolution
4% of the value stored
Configuration User interface • Liquid Crystal Display (LCD) 4 x 20 characters
• 16 key pad (6 navigation keys plus numeric/phone pad) with audible
  feedback
Configurable
parameters
• clock
• time zone
• site number
• display scaling
  (defaults are provided for each channel based on channel type)
iPack options • iPack configured via serial port connection to your PC
• serial connection direct to iPack or through logger's iPack access
  port
• Symphonie Data Retriever for Windows integrates iPack settings
Connections Sensor wiring • sensors connect to field wiring panel
• field wiring panel plugs into logger
• ground stud to connect to earth ground
• male DB25 interfaces to one optional iPack communications module
• iPack access port facilitates field programming and accepts headset
  for voice calls
• 3 SCM slots for counter SCMs
• 4 SCM slots for analog SCMs
Power
requirements
Batteries (2) 1.5 Volt D-Cell Batteries (included)
• nominal voltage: 1.5 Volts
• minimum voltage: 0.9 Volts
• battery life approximately one year, depending on configuration
External power
input
provided by any iPack
External solar
input
provided by any iPack
Other optional iPacks provide 12V power required by some sensors.
PV/Battery only iPack provides power to sensors and logger for stand
alone configurations.
Installation Mounting • mounts with 4 bolts (included) to keyed slots inside of metal shelter box
• shelter box attaches to tower with hose clamps
Tools required • screwdriver for input terminals, included
• 8 mm (5/16 inch) wrench or nut driver for logger mounting screws
• 3/8 inch wrench or nut driver for logger ground nuts
Power
requirements
Batteries (2) 1.5 Volt D-Cell Batteries (included)
• nominal voltage: 1.5 Volts
• minimum voltage: 0.9 Volts
• battery life approximately one year, depending on configuration
External power
input
provided by any iPack
External solar
input
provided by any iPack
Other optional iPacks provide 12V power required by some sensors.
PV/Battery only iPack provides power to sensors and logger for stand
alone configurations.
Environmental Operating
temperature range
-40 ¡ÆC to 65 ¡ÆC (-40 ¡ÆF to 149 ¡ÆF)
Note: display readable -30 ¡ÆC to 55 ¡ÆC (-22 ¡ÆF to 130 ¡ÆF)
Operating
humidity range
0 to 100% RH non-condensing
Lifespan 10 years +
Physical Weight 1.3 kg (2.6 pounds), including batteries
Dimensions (Including Field Wiring Panel)
22.2 cm height, 18.8 cm width, 7.7 cm depth
(8.7 x 7.4 x 3.0 in.)
Materials Faceplate injection molded black ABS
Buttons white elastomer dome keypad
Wiring panel fiberglass-epoxy terminal board, sealed gold plated pins,
zinc plated Materials screws and terminals
Enclosure weatherproof polycarbonate, meets the following specifications
• NEMA type 4, 4X & 13
• IEC : IP65
 