    Á¦Ç°¼Ò°³    NRG Symphonie Plus3
NRG Symphonie
Plus3
 
 
FEATURES
• Universal Anemometer Channels
  Six digital channels accomodate the anemometer brand of your choice.
  Digital channels do not require SCM cards.
• One-second Sample Rate
  Conforms to IEC 61400-12-1.
• Three Flex Channels
  Flex channels configure automatically based on SCM installed.
  Allows for numerous sensor configuration options.
• Password Protected Access
  Unauthorized user lockout prevents access to logger via the keypad.

SPECIFICATIONS

Description Instrument type 15 channel internet-enabled wind energy data logger
Applications • Wind resource assessment
• Turbine power performance verificat
Sensor compatibility -
counter channels
• NRG #40C anemometer
• Rain gauge
• Opto anemometer
• Reed switch anemometer
Sensor compatibility -
analog channels
• NRG Systems #200P direction vane
• NRG Systems #110S temperature sensor
• Li-Cor #200SZ pyranometer
• NRG Systems #BP20 absolute pressure (requires optional iPack power)
• RH-5X relative humidity (requires optional iPack power)
Counter channels Channels 1-3 and 13-15 are counter (digital) inputs
• Channels 1-3 and 13-15 are pre-programmed for NRG #40C anemometers or compatible sensors
• Maxumum counter input frequency: 2500 Hz
Analog channels Channels 7-12 are analog input
• Channels 7 and 8 are dedicated for NRG #200P direction vane
• Channels 9-12 use analog Signal Conditioning Modules
  (SCMs) to configure each channel for a particular sensor
Flex channels Channels 4-6 are Flex channels
• Analog or counter (digital) inputs
• Accept Signal Conditioning Modules (SCMs) to configure the channel for a particular sensor type
Data
Collection
Sampling interval One second
Averaging interval 10 minute, fixed
Real time clock Internal battery-backed
Storage medium SD Card, non-volatile FLASH
Maximum data storage 672 files
Parameters recorded
for each channel
Each data interval is time/date-stamped:
• Average
• Standard deviation
• Min*
• Max*
* min and max not used for wind direction vanes
file format • Windows compatible
• (1) 14 KB binary file per day
• Header includes site, serial number and sensor information
Software Symphonie Data Retriever for Windows
• Scales raw data
• Creates measurement database for each site
• Creates basic reports
• Maintains site and sensor information
• Configures iPacks
Reader Windows compatible SD Card reader
Data delivery • SD Card
• Internet email via GSM, CDMA, or Iridium Satellite with optional iPack
Resolution Analog measurement 0.1% of full scale (1024 counts)
Counter average 0.1% of the value stored
Analog average 0.1% of the value stored
Min / Max stored 0.4% of the value stored
Standard deviation 4% of the value stored
Configuration User interface • Liquid Crystal Display (LCD) 4 x 20 characters
• 16 key pad (6 navigation keys plus numeric/phone pad) with audible feedback
Configurable
parameters
• Clock
• Time zone
• Site number
• Display scaling (defaults are provided for each channel based
  on channel type)
iPack options • iPack configured via serial port connection to your PC
• Serial connection direct to iPack or through loggers iPack access port
• Symphonie Data Retriever for Windows integrates iPack settings
Connections Sensor wiring • Sensors connect to removeable field wiring panel
• field wiring panel plugs into logger
• Ground stud connects to earth ground with included ground cable
Expansion slots • Three (3) "Flex" SCM slots accept analog or counter (digital) SCMs
Communication ports • Four (4) SCM slots accept only analog SCMs
• Male DB25 interfaces to one optional iPack communications module
• iPack access port provides a connection to the iPack
  programming port without dismounting the iPack or logger
Power
requirements
Batteries • Two (2) 1.5 Volt D-Cell Batteries (included)
• Nominal voltage: 1.5 Volts
• Minimum voltage: 0.9 Volts
• Battery life approximately one year, depending on configuration
External power input Provided by an optional iPack
External solar input Provided by an optional iPack
Other • Optional iPacks provide 12V power required by some sensors
• PV/Battery Only iPack provides power to sensors and logger
  for stand alone configurations
Installation Mounting • Mounts with 4 bolts (included) to keyed slots inside of metal shelter box
• Shelter box mounts to tower with hose clamps
Tools required • Screwdriver for input terminals, included
• 8 mm (5/16 inch) wrench or nut driver for logger mounting screws and ground nuts
Environmental Operating
temperature range
• -40¡ÆC to 65¡ÆC (-40¡ÆF to 149¡ÆF)
• Note: display readable -30¡ÆC to 55¡ÆC (-22¡ÆF to 130¡ÆF)
Operating humidity
range
• 0 to 100% RH non-condensing
Lifespan • 10 years +
Physical Weight • 1.3 kg (2.6 pounds), including batteries
Dimensions • 22.2 cm (8.7) h x 18.8 cm (7.4) w x 7.7 cm (3.0) d, including field wiring panel
Materials Faceplate • Injection molded black ABS
Buttons • White elastomer dome keypad
Wiring panel fiberglass-epoxy terminal board, sealed gold plated pins, zinc plated screws and terminals
Enclosure Weatherproof polycarbonate, meets the following specifications:
• NEMA type 4, 4X13
• IEC: IP65
 
°ü¸®Àڷα×ÀÎ